APU引气压力有没有一个正常范围?
APU引气压力低
APU不开空调引气压力才14PSI,是不是太低了啊?
~(来自飞行员)
问
Please advise CEA the normal range of 737NG APU bleed air pressure corresponding to no bleed air load, single air conditioning pack load, dual air conditioning packs load and engine start situations.
APU bleed air pressure varies with outside air temperature, altitude and cabin temperature setting.
The following are normal APU bleed air pressures at sea level:
-- No load 0-18 psig
-- 1 pack on 26 to 45 psig
-- Both packs on 8 to 40 psig.
-- Main Engine Start approx. 43 - 44 psig
Because of the wide pressure band, do not use duct pressure as the only parameter to evaluate the health of the APU. the parameters provided in the ref AMM 49-11-00/201, Table 203, APU Operating Limits should be used as aguide in determining APU performance.
Please note: For fuel saving, Boeing does not recommend operating a single air conditioning pack while the APU is used as the air source (see the ref /C/ SL for additional information).
(SR 3-2624668790)
答
APU引气压力范围
不接空调:10~18PSI
接单空调:26~45PSI
接双空调:8~40PSI
起动主发:30~45PSI
APU引气压力低导致空调热
IGV进气:0°全关,90°全开
SCV放气:0°全开,90°全关)
APU引气ON,双空调关闭
APU引气ON,单开右组件
APU引气ON,双组件AUTO