郴州市MedAccred _AC8121电子电缆和线束组件的审核标准 (75)
35.1.11 C- Is there evidence for the inspection for damaged wire / braid / shield after stripping?YES/NO
35.1.12 C- Is there evidence that operators performing soldering of coaxial and biaxial connector assemblies are trained to the documented general hand soldering requirements of IPC/WHMA-A-620 / customer requirements / procedures?YES/NO
35.1.13 C- Is there evidence that operators performing crimping of coaxial and biaxial connector assemblies are trained to the documented general crimping requirements of IPC/WHMA-A-620 / customer requirements / procedures?YES/NO
35.2 Solder Ferrule Pins SECTION NA
35.2.1 P- Is there a procedure for the assembly and soldering of solder ferrule pins?YES/NO
35.2.2 P- Is there a procedure for the acceptance criteria for the assembly and soldering of solder ferrule pins?YES/NO
35.2.3 P- Are the procedures for soldering of solder ferrule pins linked to general soldering requirements?YES/NO
Audit Note: Linking to general soldering requirements ensures that any tooling, material, process, etc. controls for solder ferrule assembly soldering has been addressed.
35.2.4 C- Is there evidence that assembly and soldering of solder ferrule pins has been completed in accordance with procedures?YES/NO
35.2.5 C- Is there evidence that acceptance criteria for the assembly and soldering of solder ferrule pins is available and followed?YES/NO
35.2.6 C- Is there evidence that operators performing soldering of solder ferrule pins are trained to the documented general hand soldering requirements of IPC/WHMA-A-620 / customer requirements / procedures?YES/NO
35.3 Press-Fit Coaxial Connectors SECTION NA
35.3.1 P- Is there a procedure for the assembly of press fit coaxial connectors?YES/NO
35.3.2 P- Is there evidence for a link between manufacturer’s recommended instructions and/ or design requirements for the press-fit connector assembly and shop floor instructions?YES/NO