荣事达冰箱故障代码,附传感器不同温度下的阻值
Tx(℃) |
Rmin(kΩ) |
Rnom(kΩ) |
Rmax(kΩ) |
-30.0 |
31.90 |
33.81 |
35.82 |
-29.0 |
30.09 |
31.85 |
33.70 |
-28.0 |
28.39 |
30.01 |
31.72 |
-27.0 |
26.79 |
28.29 |
29.87 |
-26.0 |
25.30 |
26.68 |
28.14 |
-25.0 |
23.89 |
25.17 |
26.51 |
-24.0 |
22.57 |
23.76 |
24.99 |
-23.0 |
21.33 |
22.43 |
23.57 |
-22.0 |
20.17 |
21.18 |
22.23 |
-21.0 |
19.07 |
20.01 |
20.97 |
-20.0 |
18.04 |
18.90 |
19.80 |
-19.0 |
17.08 |
17.87 |
18.69 |
-18.0 |
16.16 |
16.90 |
17.66 |
-17.0 |
15.31 |
15.98 |
16.68 |
-16.0 |
14.50 |
15.12 |
15.77 |
-15.0 |
13.74 |
14.31 |
14.90 |
-14.0 |
13.02 |
13.55 |
14.10 |
-13.0 |
12.34 |
12.83 |
13.33 |
-12.0 |
11.71 |
12.16 |
12.62 |
-11.0 |
11.11 |
11.52 |
11.94 |
-10.0 |
10.54 |
10.92 |
11.31 |
-9.0 |
10.00 |
10.36 |
10.71 |
-8.0 |
9.496 |
9.820 |
10.15 |
-7.0 |
9.019 |
9.316 |
9.619 |
-6.0 |
8.568 |
8.841 |
9.119 |
-5.0 |
8.141 |
8.392 |
8.647 |
-4.0 |
7.738 |
7.968 |
8.202 |
-3.0 |
7.357 |
7.568 |
7.782 |
-2.0 |
6.997 |
7.190 |
7.386 |
-1.0 |
6.656 |
6.833 |
7.011 |
0.0 |
6.333 |
6.495 |
6.658 |
Tx(℃) |
Rmin(kΩ) |
Rnom(kΩ) |
Rmax(kΩ) |
1.0 |
6.028 |
6.175 |
6.324 |
2.0 |
5.378 |
5.873 |
6.008 |
3.0 |
5.464 |
5.587 |
5.710 |
4.0 |
5.205 |
5.316 |
5.428 |
5.0 |
4.959 |
5.060 |
5.161 |
6.0 |
4.717 |
4.818 |
4.919 |
7.0 |
4.488 |
4.589 |
4.690 |
8.0 |
4.272 |
4.372 |
4.472 |
9.0 |
4.067 |
4.167 |
4.256 |
10.0 |
3.874 |
3.972 |
4.071 |
11.0 |
3.690 |
3.788 |
3.886 |
12.0 |
3.517 |
3.613 |
3.710 |
13.0 |
3.352 |
3.447 |
3.543 |
14.0 |
3.197 |
3.290 |
3.385 |
15.0 |
3.049 |
3.141 |
3.234 |
16.0 |
2.909 |
2.999 |
3.091 |
17.0 |
2.776 |
2.865 |
2.956 |
18.0 |
2.650 |
2.737 |
2.827 |
19.0 |
2.530 |
2.616 |
2.704 |
20.0 |
2.417 |
2.501 |
2.587 |
21.0 |
2.309 |
2.391 |
2.476 |
22.0 |
2.206 |
2.287 |
2.370 |
23.0 |
2.109 |
2.188 |
2.270 |
24.0 |
2.016 |
2.094 |
2.174 |
25.0 |
1.929 |
2.005 |
2.083 |
26.0 |
1.845 |
1.919 |
1.996 |
27.0 |
1.765 |
1.838 |
1.913 |
28.0 |
1.690 |
1.761 |
1.834 |
29.0 |
1.618 |
1.687 |
1.759 |
30.0 |
1.549 |
1.617 |
1.687 |
代码 |
故障原因 |
重点检查 |
型号 |
E1 |
冷藏室感温头短路或断路 |
相应接插件和传感器回路 |
186A/E216A/E258B/E208/E 248W/E,195/E,205/E,262/E |
E2 |
冷冻室感温头短路或断路 |
相应接插件和传感器回路 |
248W/E |
E2 |
微冻室传感器短路或断路 |
相应接插件和传感器回路 |
258B/E,208/E |
E3 |
冷冻室感温头短路或断路 |
相应接插件和传感器回路 |
186A/E216A/E258B/E208/E 195/E、205/E、262/E |
E3 |
冷冻室化霜传感器短路或断路 |
相应接插件和传感器回路 |
248W/E |
E4 |
环温传感器短路或断路 |
相应接插件和传感器回路 |
208/E,195/E,205/E |
E4 |
E2PROM出现读写故障 |
248W/E |
|
E5 |
冷冻室超温报警 |
248W/E |
|
E5 |
E2PROM出现读写故障 |
186A/E216A/E258B/E208/E,262/E |
|
E6 |
环温传感器短路或断路 |
相应接插件和传感器回路 |
248W/E |
E6 |
冷冻室温度持续过高 |
制冷剂泄漏 |
186A/E216A/E195/E205/E 262/E,265/E |
E7 |
通讯故障 |
接插件及线是否接错或断路 |
258B/E、195/E、205/E |
rS |
冷藏室传感器故障 |
212He212Hse192He192Hse |
|
dS |
副蒸发器传感器故障 |
212He212Hse192He192Hse |
fS |
冷冻室传感器故障 |
212He212Hse192He192Hse |
eS |
外部传感器故障 |
212He212Hse192He192Hse |
L |
感温头温度过低或感温头温度偏移 |
186A/E218A/E258B/E208/E |
H |
感温头温度过高或感温头温度偏移 |
186A/E219A/E258B/E208/E |
DR |
开门报警 |
248W/E |