ResilientChannel: genieclip

10 Jul Resilient Channel: If You Use It, Don’t Screw It Up!

Posted at 16:03hin FeaturesbyAdmin7 Comments

0 Likes
Share

According to building codes, party floor/ceiling assemblies must provide a minimum Sound Transmission Class (STC) rating of 50. To achieve this level of isolation, designers often spec resilient channel (aka rez bar or Z bar) with two layers of gypsum wallboard.

However, there’s a myth that says resilient channel can’t support multiple layers of gypsum wallboard in floor/ceiling assemblies. While we’re not sure where the myth originates, evidence shows that resilient channel attached to the underside of floor joists can successfully support two layers of 1/2-inch or 5/8-inch gypsum wallboard.

Tests conducted by United States Gypsum, a manufacturer of resilient channel, demonstrate that resilient channel can support multiple layers of wallboard. In addition, the Institute for Research in Construction, a division of the Canadian National Research Council, has performed sound isolation tests on both one and two layers of wallboard supported from resilient channel. In fact, such floor assemblies are listed in the Canadian National Building Code.

Some contractors and suppliers recommend installing one layer of wallboard directly to the underside of the joists, strapping that with resilient channel, and then adding a second layer of wallboard to the resilient channel. Yet this construction wastes the acoustical benefits of the second layer of wallboard.

For example, consider the F4d floor in the Canadian National Building Code, which consists of the following:

  • 5 mm plywood, OSB, or waferboard, or 17 mm tongue-and-groove lumber;
  • 38 mm x 235 mm wood joists spaced at no more than 600 mm o.c.;
  • absorptive material in the cavity; and
  • two layers of 12.7 mm Type X gypsum wallboard on the ceiling side.

This floor has a typical STC rating of 36 and an Impact Insulation Class rating (IIC) of 32.

If the F4d floor assembly is modified with a layer of resilient channel between the two layers of wallboard, the assembly becomes an F7d floor with an STC rating of 37 and IIC rating of 30.

However, if the resilient channel is placed between the wallboard and the floor joists with 400 mm spacing between the channels, the assembly becomes an F9g floor. This assembly has an STC rating of 54 and IIC rating of 47.

By installing resilient channel in the correct location, you can optimize the sound and impact isolation qualities of floor and ceiling partitions—and if your plan already calls for resilient channel, you won’t need to upgrade your building materials.

Short Circuiting Resilient Channel

Another problem can occur when installers unintentionally thread screws through the drywall into the joists. It’s a common mistake when longer screws are used. By penetrating the joist, a screw “short circuits” the isolated wallboard, and creates a path for noise to travel through the floor assembly. Understandably, short circuits are difficult to identify and often limit the acoustical benefits of any floor/ceiling or wall assembly.

By using resilient clips, you can secure wallboard while preventing short circuits. Designs vary among manufacturers, e.g., Genie Clip, IsoMax, SonusClip, or RSIC-1, yet most resilient clips work the same way: They make sure that both the wallboard and the screws are isolated from the joists. In addition, resilient clips are compatible with any length of screw, so installers don’t have to deal with the hassle of carrying multiple lengths of fasteners.

Good acoustical design leads to fewer noise complaints. This can save you from expensive remedial work in the future. Remember, whether your project is a residential, commercial, or mixed-use development, don’t believe the myths. Instead, get in touch with us.

Our team of acoustical engineers can review project drawings to assess the acoustical performance of floors, ceilings, and walls, as well as windows and building envelopes. We have the experience and skills to provide insightful, analysis-based recommendations to improve sound isolation, control noise from mechanical systems, and limit traffic and community noise and vibration.

(0)